Description of discharge measurements: Erken, Outlet in Stensta

Document
11676.1/4CQirxXdy-q3nwUuQ93IuUtG (link)
SITES_WB-Q_ERK-STE_discharge-description_2006-2021.pdf

Description of the discharge measurement installation at the lake Erken - Outlet in Stensta. Method used: Druck relative pressure sensor, salt slug method; Discharge rating curve (Q=f(SL)): Q=3.994SL^2-70.237172SL+308.23464359 where: Q=discharge (m3 s-1), SL=stream level (m) Sampling point: Erken - Outlet (Stensta), Latitude: 59.85061, Longitude: 18.70307, Altitude: 2.1 m a.s.l., Catchment area: 140.895 km2

Erken Laboratory (2022). Description of discharge measurements: Erken, Outlet in Stensta. Swedish Infrastructure for Ecosystem Science (SITES). https://hdl.handle.net/11676.1/4CQirxXdy-q3nwUuQ93IuUtG
BibTex
@misc{https://hdl.handle.net/11676.1/4CQirxXdy-q3nwUuQ93IuUtG,
  author={Erken Laboratory},
  title={Description of discharge measurements: Erken, Outlet in Stensta},
  year={2022},
  url={https://hdl.handle.net/11676.1/4CQirxXdy-q3nwUuQ93IuUtG},
  publisher={Erken Laboratory},
  copyright={https://meta.fieldsites.se/ontologies/sites/sitesLicence},
  pid={11676.1/4CQirxXdy-q3nwUuQ93IuUtG}
}
RIS
TY - DATA
T1 - Description of discharge measurements: Erken, Outlet in Stensta
ID - 11676.1/4CQirxXdy-q3nwUuQ93IuUtG
PY - 2022
UR - https://hdl.handle.net/11676.1/4CQirxXdy-q3nwUuQ93IuUtG
PB - Erken Laboratory
AU - Erken Laboratory
ER - 