Description of the discharge measurement installation at the lake Erken - Outlet in Stensta. Method used: Druck relative pressure sensor, salt slug method; Discharge rating curve (Q=f(SL)): Q=3.994SL^2-70.237172SL+308.23464359 where: Q=discharge (m3 s-1), SL=stream level (m) Sampling point: Erken - Outlet (Stensta), Latitude: 59.85061, Longitude: 18.70307, Altitude: 2.1 m a.s.l., Catchment area: 140.895 km2
@misc{https://hdl.handle.net/11676.1/4CQirxXdy-q3nwUuQ93IuUtG, author={Erken Laboratory}, title={Description of discharge measurements: Erken, Outlet in Stensta}, year={2022}, url={https://hdl.handle.net/11676.1/4CQirxXdy-q3nwUuQ93IuUtG}, publisher={Erken Laboratory}, copyright={https://meta.fieldsites.se/ontologies/sites/sitesLicence}, pid={11676.1/4CQirxXdy-q3nwUuQ93IuUtG} }
TY - DATA T1 - Description of discharge measurements: Erken, Outlet in Stensta ID - 11676.1/4CQirxXdy-q3nwUuQ93IuUtG PY - 2022 UR - https://hdl.handle.net/11676.1/4CQirxXdy-q3nwUuQ93IuUtG PB - Erken Laboratory AU - Erken Laboratory ER -